Scribers

SCRIBERS

The scratch line will not be misaligned due to the number of scribings. It is possible to perform scratching operations without directly touching the sample. By applying a certain amount of pressure with a spring, it is possible to do the scraping work without relying on human power. Precise and easy preparation of samples for cross-sectional observation. It is the most suitable equipment for development experiments and quality control applications.

Scribers

SC-100
Size W225mm×D212mm×H297mm
(W8.8″×D8.3″×H11.6″)
Weight 10kg (22lbs)
Work Size φ100mm×t4mm (3.9″×t0.1″)
Work Moving X direction 100mm (3.9″)
Work Rotating 360 degree
Scribe Direction Y direction 122mm (4.8″)
Scribe Angle 50 – 70 degree
Scribe Load 0g – 350g (0lbs – 0.7lbs)
This is a precision manual scriber that achieves high accuracy at a low price.
Samples up to 100mm in diameter can be installed.
There is no need to directly touch or press the sample by hand.
It does not rely on human power, and the force of the spring achieves a constant pressure for scribing.
It is easy to prepare a sample for cross-sectional observation with simple operation.
It is possible to set the angle of the sample with one touch.
It is best suited for space-saving development experiments and quality control.
The standard specification allows observation with a 25x monocular.
38x monocular or CCD camera can be installed as an option.
SC-150
Size W325mm×D299mm×H292mm
(W12.7″×D11.7″×H11.4″)
Weight 15kg (33lbs)
Work Size φ155mm × t4 (6.1″×t0.1″)
Work Moving X direction 160mm (6.2″)
Work Rotating 360 degree
Scribe Direction Y direction 170mm (6.6″)
Scribe Angle 50 – 70 degree
Scribe Load 10g – 400g (0.02lbs – 0.8lbs)
This is a precision manual scriber that achieves high accuracy.
A sample of up to 150 mm in diameter can be set up.
There is no need to directly touch or press the sample.
It does not rely on human power, and the force of the spring achieves a constant pressure for scribing.
It is easy to prepare a sample for cross-sectional observation with simple operation.
It is best suited for space-saving development experiments and quality control.
The standard specification allows observation with a 25x monocular.
38x monocular or CCD camera can be installed as an option.
SC-300
Size W425mm×D460mm×H275mm
(W16.7″×D18.1″×H10.8″)
Weight 27kg (59.5lbs)
Work Size φ300mm × t4 (11.8″×t0.1″)
Work Moving X direction 160mm (6.2″)
Work Rotating 360 degree
Slide Stroke -155mm to+155mm
(-6.1″ to 6.1″)
Scribe Direction Y direction 170mm (6.6″)
Scribe Angle 50 – 70 degree
Scribe Load 0g – 400g (0lbs – 0.8lbs)
This is a precision manual scriber that achieves a high level of accuracy.
It is capable of injuring wafers up to 12 inches in size.
The vacuum chuck makes it possible to work without directly touching or pressing the sample.
It does not rely on human power, and the force of the spring achieves a constant pressure for scribing.
It is easy to prepare a sample for cross-sectional observation with simple operation.
A linear scale with a minimum unit of 10 µm is used for positioning.
The standard specification allows observation with a 25x monocular.
38x monocular or CCD camera can be installed as an option.
SC-400
Size W500mm×D490mm×H170mm
(W19.6″×D19.2″×H6.6″)
Weight 10kg (22lbs)
Work Size 400mm×400mm×t5mm
(15.7″×15.7″×0.2″)
Slide Mechanism Vernier Scale
Scribe Load 300g, 500g, 1000g
(0.6lbs, 1.1lbs, 2.2lbs)
Scribe Load
Adjustment
Spring replacement
This is a precision manual scriber that achieves high accuracy.
This equipment is best suited for scribing liquid crystal glass.
A large degree of freedom is realized with a workpiece thickness that can be scratched from 0 to 5 mm.
The sliding rails on both sides allow for a smooth and constant pressure.
It is easy to prepare a sample for cross-sectional observation with simple operation.
It is possible to mount the sample holding by the vacuum chuck method.
You can draw lines at equal intervals on the stage to improve work efficiency.

 

Scribe Needles

Model Feature
It is the most suitable for scratching Si, GaAs, Inp and other samples.
Scribe needle (OS3P) does not have a line at the bottom of the needle. (For distinction, the line is included in the scratch needle (3PR).
OS3P
Ideal for scratching sapphire, quartz glass and other samples.
To distinguish it from an Scribe needle (OS3P), there is a line at the bottom of the needle.
3PR
Carbide roller blades for use with precision manual scribers. This is the most suitable needle for injuring samples such as glass.
Roller Needle

 

Breaking Jigs

Model Feature
A precision manual scriber device can be used to break specimens in accordance with the scribe line. The stopper holds the sample from both sides and bends the jig to break it.
Breaking Jig 2in.
A precision manual scriber device can be used to break specimens in accordance with the scribe line. The stopper holds the sample from both sides and bends the jig to break it.
Breaking Jig 4in.
Fracture the specimen in accordance with the drawing line and breaking jig guidelines. The sample is held with one hand while breaking.
Plier

 

 

Thank you for reading this to the end.